Two Models — Two mattress widths |
Allura II 100 (1000mm) |
Allura II 120 (Mighty) (1200mm) |
Allura II 100 Bed with optional timber cover for footboard and shown with Cherusker Bedside Cabinet ⁄ Overbed Table
Allura II Bed with Click-on safety sides
Features — Details of Allura II Care Bed features
The Mattress Base with steel slat floor:
“Allura II 100”, 1000mm x 2000mm,
“Allura II 120 (Mighty)”, 1200mm x 2000mm
250 kg safe working load, 4-section mattress base, electrically adjustable. Applies to all Allura II models. (weight includes mattress & accessories)
Handset with selective locking and auto-contour function. Water resistant—IP64. Flush keys avoid accidental operation.
Linak Drive System: 24 Volt drive system as standard
Power saving switch mode. Long intervals for maintenance. Residents are optimally protected, as all live 240 Volt components are outside the bed.
Fall protection height of side rails: approx. 400mm
Mattress and pressure ulcer systems of a maximum thickness of 160mm can be placed on the care bed without adaptable side rail extensions.
Lowering Footend – reverse trendelenburg
Shows bed in chair position.
Lowest entry height at 300mm
The mattress surface height adjustment can be adjusted from 300 to 800 mm.
The unusually large adjustment range of 500 mm ensures a maximum of comfort care.
Highest working height of 800mm
The highest mattress base position of 800mm provides a comfortable working height which is kind to carers' backs.
So this all–purpose bed is the only type of bed you'll need.
Lower-leg rest
Electric Knee Break with manually adjustable lower leg rest.
High quality castors
100mm high-quality, rugged Tente castors.
Optional Timber panels to cover the chassis (can be retrofitting).
Compact delivery and storage on storage aid ⁄ transportation aid (similar to illustration).
A unique safe 24 Volt DC Linak drive system is standard with the bed. Having the 240 volts isolated, away from the bed and only safe 24 Volts DC at the bed ensures a safer environment for residents and maintenance staff.
Energy-saving with low voltage
ESSENTIALLY BETTER
* Compared to 240-volt systems, assuming approx. 5 adjustments per day
The external transformer unit produces a safety extra-low voltage directly at the power socket.
The Allura beds are supplied with extra-low voltage as standard. This is achieved with an external transformer that reduces the voltage directly at the power socket to 24-volts to ensure that there are no live 240 volt components near the resident. This not only increases safety, but also significantly helps to reduce energy costs and electromagnetic pollution, and to protect the environment.
Features at a Glance
Optional Features — for Allura II Care Bed
Bed Extension (Optional)
Bed extension (with 4 longer wooden side rails 220cm) – can be retrofitted.
Timber Footend Surround (Optional)
More information on Burmeier Accessories
Safety Sides Easy Click
Innovative design
The timeless, innovative design underlies Burmeier’s quality philosophy; this bed looks very attractive and offers uncompromisingly high quality and durability.
The adjustment range of 500mm allows the kingsize nursing bed to be used as either a low-entry bed or as a standard nursing bed.
The highest mattress position of 800mm allows nursing staff to work comfortably without stressing their backs.
Having beds according to type of use is no longer necessary. One bed for all cases.
Allura II 100 Bed with optional timber cover for footboard and shown with Cherusker Bedside Cabinet ⁄ Overbed Table
Allura II 120 (Mighty) Bed (with optional timber cover for footboard) shown in chair position
Specifications — Allura 100 & 120 (Mighty)
Allura II Care Bed Specifications | ||
---|---|---|
Capacity: | 250kg | |
Length: | approx. 2240mm | |
Bed extension: | approx. 200mm | |
Width: | Allura II 100: | approx. 1110mm |
Allura II 120 (Mighty): | approx. 1310mm | |
High ⁄ Low: | 300 to 800 mm, range = 500 mm | |
Mattress Base Size: | Allura II 100: | 1000mm x 2000mm metal slats |
Allura II 120 (Mighty): | 1200mm x 2000mm metal slats | |
Mattress base dismantles | ||
Reverse Trendelenberg | 14° | |
Ground Clearance | 130mm | |
Total Weight | Allura II 100 — 120kg | Allura II 120 (Mighty) — 133kg |
Castors: | 100mm High–quality, individually locking rugged Tente castors | |
Lift Operation: | 24 Volt (switch mode) Fully Electric | |
24-volt drive concept with external transformer : | ||
Backrest: | 0° – 70° | Manual CPR release |
Knee break: | 0° – 30° | |
Full-length safety side: | ||
Protective height of safety sides: | 380mm | |
Finish: | Metal parts sealed with a polyester powder lacquer coating, colour topaz.
Wooden surround with integrated side frames. Working timber areas melamine covered—0.6mm. |
|
Natural Beech decor (R 24010 VV) | ||
ARTG number: | 208844 |
Dimensions — Allura 100 & 120 (Mighty)
Product Codes — Allura 100, Allura 120 (Mighty) and accessories
Allura II Care Beds Codes | |
---|---|
EV94B4AAIIW | Allura II 100 Care Bed – 4 section, 1000mm x 2000mm base |
EV94B8EKAAW | Allura II 100 Care Bed – 200mm extension to mattress platform |
EV94B8CFAAW | Allura II 100 Care Bed – Timber Cover for Footboard |
EV94B8CHAAW | Allura II 100 Care Bed – Timber Cover for Headboard |
EV94B4AAIIM | Allura II 120 Mighty Care Bed – 4 section, 1200mm x 2000mm base |
EV94B4AAM | Allura Mighty Care Bed – 4 section, 1200mm x 2000mm base |
EV94B8CFAAM | Allura Mighty Care Bed – Timber Cover for Footboard |
EV94B8CHAAM | Allura Mighty Care Bed – Timber Cover for Headboard |
EV94B8AAIIM | Allura Mighty Care Bed – 200mm extension to mattress platform |
Mattress Codes — to suit Allura II Care Beds
Mattress Codes – Allura II 100 Bed
EV9731 – Mid Pressure Care Mattress 2000 x 1000 x 150,
EV9732 – Frail Pressure Care Mattress 2000 x 1000 x 150,
EV9733 – Maxi Pressure Care Mattress 2000 x 1000 x 180
Mattress Codes – Allura 120 (Mighty) Beds
EV9743 – Maxi Pressure Care Mattress 2000 x 1200 x 180 (Bravo Cover)