The heavy-duty bed – our Gigant provides heavier occupants with a high level of comfort.
(With optional KSG Combinable Side Rails on one side)
Impressive Key Features of Gigant at a Glance:
A bariatric SAFE working load of 350kg:
The mattress base of the “Gigant II” Care Bed can accommodate a safe working load of 350kg. Residents will appreciate the generous 1200mm wide mattress base, and the length can be extended to 2200mm if necessary (bed extension available as optional accessory).
Burmeier Quality and Durability
This care bed “Gigant” is extremely sturdily constructed, so that it fulfills the requirements in daily care perfectly. The high quality ensures you have a nursing home bed which is durable, robust, easy to maintain and which decisively minimizes follow-up costs.
Mattress Height Adjustment – 400mm to 800mm
The highest mattress position of 800mm allows nursing staff to work comfortably without stressing their backs.
Performance
4–section mattress base 1200 x 2000mm, mattress surface height adjustment from 400 to 800mm, powered adjustment of back rest (retracting) as well as the height of the mattress surface. The footend of the bed can be lowered by tilting the mattress base using the hand control to facilitate a chair position.
24 Volt Drive System as standard
For the safety of patient and user, low-voltage 24 volts is produced by means of a central control unit transformer. All drive motors and the hand switch are hooked up to the central control unit by plug-in connections and work with the 24 volt safety low-voltage.
Mobility and comfort of Gigant
Early mobilisation of those in need of care is of increasing importance in the daily care routine of today. This is why the Gigant II assists this process with special functions. The mobilisation support in the combinable split safety sides (optional) with its ergonomic knob provides the occupant of the bed with a secure grip and enhanced safety. The combinable split safety sides also comply with the requirements in place to restrict the use of restraint measures. It can also be combined with full-length safety sides.
Sitting position — Makes breathing easier
Gigant II Care Bed Features
The Bed Ends with wooden surrounds in a modern design, plastic panels on the chassis and side facings lend a home-like ambience
The emergency release of the backrest possible from any bed position. In the event of power supply outages or electrical drive system failures, the raised backrest can be lowered by hand.
Extremely sturdy safety side construction.
The locating sleeve for mobilisation support (left) and locking box (right) to disable hand control buttons. The handset and locking box are connected to one another. This means that it is only possible to use the adjustment functions on the handset if the corresponding function is activated on the locking box.
Hand Control
Water resistant—IP66. Simultaneous adjustment of the back and thigh rest (Auto-contour). For safety reasons, the handset features a number of locking functions.
These locking functions can be used to lock the handset functions and prevent the bed from being adjusted to protect patients‘ in poor clinical condition. Elastic hook can be hooked onto the bed.
24 Volt drive system as standard
For the safety of patient and user, safety low-voltage of 24 volt is produced by means of a transformer.
All drive motors and the hand switch are hooked up to the central control unit by plug-in connections and work with the 24 volt safety low-voltage.
Mains cable holder
The head section of the bed is fitted with a mains cable holder on each side of the bed underneath the mattress base frame.
The mains cable must always be hooked into the mains cable holder before the bed is moved.
Individually locking, robust TENTE castors.
Electric Knee Break with manually adjustable lower leg rest.
Bed extension including longer safety sides and side boards.
Patient Lifting Pole with grab handle can be attached. The patient can use this grab handle to sit up and readjust their position.
Under bed clearance for all commercially available lifters.
Gigant Heavy Duty Bed Specifications
Safe Working Load: | 350kg | |
Length: | approx. 2220mm | |
Width: | approx. 1340mm | |
High / Low: | 400 to 800 mm, range = 400 mm | |
Mattress Base Size: | EV94B4GTII (Beech) | 1200mm x 2000mm |
Reverse Trendelenberg | ||
Castors: | 100mm Individually Locking Tente Castors | |
Lift Operation: | 24 Volt Fully Electric | |
Backrest: | 0° - 70° | |
Knee break: | 0° - 26° | |
Foot end down: | To 10° | |
Side Rails: | DSG – Continuous Side Rail on one or both sides
KSG – Combined Side Rail on one or both sides |
|
Finish: | Frame - Polyester Powder Coated
Wooden surround with integrated side frames. Working timber areas melamine covered—0.6mm. |
|
ARTG number: | 208844 |
Gigant Heavy Duty Bed and Mattress Codes
Gigant Heavy Duty Bed Codes | |
---|---|
EV94B4GTII – 1200mm | Gigant Heavy Duty Bed, 4 section (Beech) |
EV9743 – 1200mm | Maxi Pressure Care Mattress 2000 x 1200 x 180 (Bravo Cover) |
Safety sides for Gigant – Preserving mobility
DSG Full length safety sides
The bed is fitted with continuous full length safety sides to protect the occupant or patient from accidentally falling out of bed. The safety sides can be raised and lowered in succession to protect the occupant while they are being raised and lowered.
KSG Split (combinable) safety sides
Burmeier Gigant II Heavy Duty Bed with DSG & optional KSG Side Rails.
Gigant with optional KSG (Combined Side Rail) on one side.
© 2024 Evocare Australia Pty Limited. All rights reserved. ABN 98 078 566 604