Allura II Care Bed comes in 2 widths, Allura II 100—1000mm, Allura II 120—1200mm.
Burmeier Allura II Care 4 Section Electric Nursing Home Beds
Three Models — Two mattress widths
Allura II 100 (1000mm)
Allura II 120 (1200mm)
Allura Mighty (1200mm)
mouseover for larger image
Allura II Bed (with optional timber cover for footboard)
Allura II Bed shown with Cherusker Bedside Locker ⁄ Overbed Table
Features at a Glance
Kingsize 4-section mattress base has metal slats and is able to be dismantled.
Safe working load: 250kg
Selectively locking handset with auto-contour and robust construction
Adjustable Back Support and Upper Leg Rest
100mm high–quality, rugged Tente castors
Wooden surround with integrated side frames in beech finish, optional headend and footend covers available
Linak drive system with 24 Volt technology, live 240 Volt components are outside the bed
All Allura beds except the Mighty have individual drive motors for functions – the Mighty has a twin drive motor for backrest and knee break functions
Design
The timeless, innovative design underlies Burmeier’s quality philosophy; this bed looks very attractive and offers uncompromisingly high quality and durability.
Mattress Height Adjustment – 300mm to 800mm
The adjustment range of 500mm allows the kingsize nursing bed to be used as either a low-entry bed or as a standard nursing bed.
The highest mattress position of 800mm allows nursing staff to work comfortably without stressing their backs.
Having beds according to type of use is no longer necessary. One bed for all cases.
Allura II Care Bed Specifications
Capacity:
250kg
Length:
approx. 2240mm
Width:
Allura II 100:
approx. 1110mm
Allura II 120:
approx. 1210mm
Allura Mighty:
approx. 1310mm
High ⁄ Low:
300 to 800 mm, range = 500 mm
Mattress Base Size:
Allura II 100:
1000mm x 2000mm metal slats
Allura II 120:
1200mm x 2000mm metal slats
Allura Mighty:
1200mm x 2000mm mesh
Reverse Trendelenberg
14°
Ground Clearance
130mm
Total Weight
Allura II 100 — 120kg
Allura II 120 — 133kg
Castors:
100mm High–quality, rugged Tente castors
Lift Operation:
24 Volt (switch mode) Fully Electric
Backrest:
0° – 70°
Manual CPR release
Knee break:
0° – 30°
Finish:
Metal parts sealed with a polyester powder lacquer coating, colour topaz.
Wooden surround with integrated side frames.
Working timber areas melamine covered—0.6mm.
ARTG number:
208844
Allura II Care Beds Codes
EV94B4AAIIW
Allura II 100 Care Bed – 4 section, 1000mm x 2000mm base
EV94B8EKAAW
Allura II 100 Care Bed – 200mm extension to mattress platform
EV94B8CFAAW
Allura II 100 Care Bed – Timber Cover for Footboard
EV94B8CHAAW
Allura II 100 Care Bed – Timber Cover for Headboard
EV94B4AAMII
Allura II 120 Care Bed – 4 section, 1200mm x 2000mm base
EV94B4AAM
Allura II Mighty Care Bed – 4 section, 1200mm x 2000mm base
EV94B8CFAAM
Allura Mighty Care Bed – Timber Cover for Footboard
EV94B8CHAAM
Allura Mighty Care Bed – Timber Cover for Headboard
EV94B8EKAAM
Allura Mighty Care Bed – 200mm extension to mattress platform
Having the 240 Volts isolated, away from the bed and only 24 Volts at the bed means a safer environment for resident and maintenance personal.
The switch mode of this system means that unlike other electric beds there is no current flowing through the bed control box and motors until a hand control button is pressed -
a substantial saving from not being on standby.
With this system too, the maintenance intervals can be increased to 2 years.
Leakage current at the nursing bed need now only be measured every 10 years.
Residents are optimally protected, as all live 240 Volt components are outside the bed.
Openbus technology available on all Allura Beds except the Mighty.
Allura Mighty Bed (with optional timber cover for footboard) shown with Cherusker Bedside Locker/Overbed Table
Allura II 120 Bed (with optional timber cover for footboard) shown with Hermann Bedside Locker/Overbed Table
Mattress Codes – Allura II 100 Bed
EV9731 – Mid Pressure Care Mattress 2000 x 1000 x 150,
EV9732 – Frail Pressure Care Mattress 2000 x 1000 x 150,
EV9733 – Maxi Pressure Care Mattress 2000 x 1000 x 180
Mattress Codes – Allura Mighty Beds
EV9743 – Maxi Pressure Care Mattress 2000 x 1200 x 180 (Bravo Cover)
Allura II Care Bed Features;
mouseover for larger image
The Mattress Base with steel slat floor:
“Allura II 100”, 1000mm x 2000mm,
“Allura II 120”, 1200mm x 2000mm,
“Allura Mighty”, 1200mm x 2000mm
250 kg safe working load, 4-section mattress base, electrically adjustable.
(applies to all Allura II models).
(weight includes mattress & accessories)
mouseover for larger image
Handset with selective locking and auto-contour function. Water resistant—IP64.
Flush keys avoid accidental operation.
mouseover for larger image
Linak Drive System: 24 Volt drive system as standard Power saving switch mode. Long intervals for maintenance. Residents are optimally protected, as all live 240 Volt components are outside the bed.
Fall protection height of side rails: approx. 400mm Mattress and pressure ulcer systems of a maximum thickness of 160mm can be placed on the care bed without adaptable side rail extensions.
mouseover for larger image
Lowering Footend – reverse trendelenburg Shows bed in chair position.
mouseover for larger image
Lowest entry height at 300mm The mattress surface height adjustment can be adjusted from 300 to 800 mm.
The unusually large adjustment range of 500 mm ensures a maximum of comfort care.
mouseover for larger image
Highest working height of 800mm The highest mattress base position of 800mm provides a comfortable working height which is kind to carers' backs.
So this all–purpose bed is the only type of bed you'll need.
mouseover for larger image
LOWER-LEG rest Electric Knee Break with manually adjustable lower leg rest.